PDU-70 POWER DISTRIBUTION UNIT FOR ELECTRIC VEHICLE

PDU-70 POWER DISTRIBUTION UNIT FOR ELECTRIC VEHICLE

The PDU-70 is a power distribution unit developed by NERO Industries engineers in the scope of electrical vehicle application. The PDU-70 is a safe, intelligent and versatile power distribution unit in a compact form with configurable multiple power inputs and outputs. The smart control unit provides easy integration for high voltage/high current system applications. As typical application fields; the PDU-70 is suitable for medium and heavy duty electric/hybrid vehicle power distribution and energy control. Some important features are as follows:
– High voltage power inputs for standard charging
– Isolated voltage reading at the high voltage inputs and outputs (up to 1000 VDC)
– High voltage safety interlock line (HVIL)
– Interlock line controlled high voltage battery relay control outputs
– Earth insulation level measurement
– Secondary passive high voltage DC bus energy sinking
– Active high voltage DC bus energy sinking (Through PTC Thermistors)
– Pre-charge circuit at all high-voltage power outputs
– Fuse protection at high voltage outputs
– Overvoltage, undervoltage, overcurrent and over-temperature protection
– Low power mode

Name *
Field is required!
Field is required!
Last name*
Field is required!
Field is required!
Company name *
Field is required!
Field is required!
Street address
Field is required!
Field is required!
Postal code
Field is required!
Field is required!
City *
Field is required!
Field is required!
  • Country *
  • Afghanistan
  • Albania
  • Algeria
  • Andorra
  • Angola
  • Antigua and Barbuda
  • Argentina
  • Armenia
  • Australia
  • Austria
  • Azerbaijan
  • Bahamas
  • Bahrain
  • Bangladesh
  • Barbados
  • Belarus
  • Belgium
  • Belize
  • Benin
  • Bhutan
  • Bolivia (Plurinational State of)
  • Bosnia and Herzegovina
  • Botswana
  • Brazil
  • Brunei Darussalam
  • Bulgaria
  • Burkina Faso
  • Burundi
  • Cabo Verde
  • Cambodia
  • Cameroon
  • Canada
  • Central African Republic
  • Chad
  • Chile
  • China
  • Colombia
  • Comoros
  • Congo
  • Cook Islands
  • Costa Rica
  • Croatia
  • Cuba
  • Cyprus
  • Czechia
  • Democratic People's Republic of Korea
  • Democratic Republic of the Congo
  • Denmark
  • Djibouti
  • Dominica
  • Dominican Republic
  • Ecuador
  • Egypt
  • El Salvador
  • Equatorial Guinea
  • Eritrea
  • Estonia
  • Eswatini
  • Ethiopia
  • Faroe Islands
  • Fiji
  • Finland
  • France
  • Gabon
  • Gambia
  • Georgia
  • Germany
  • Ghana
  • Greece
  • Grenada
  • Guatemala
  • Guinea
  • Guinea-Bissau
  • Guyana
  • Haiti
  • Honduras
  • Hungary
  • Iceland
  • India
  • Indonesia
  • Iran (Islamic Republic of)
  • Iraq
  • Ireland
  • Israel
  • Italy
  • Jamaica
  • Japan
  • Jordan
  • Kazakhstan
  • Kenya
  • Kiribati
  • Kuwait
  • Kyrgyzstan
  • Lao People's Democratic Republic
  • Latvia
  • Lebanon
  • Lesotho
  • Liberia
  • Libya
  • Lithuania
  • Luxembourg
  • Madagascar
  • Malawi
  • Malaysia
  • Maldives
  • Mali
  • Malta
  • Marshall Islands
  • Mauritania
  • Mauritius
  • Mexico
  • Micronesia (Federated States of)
  • Monaco
  • Mongolia
  • Montenegro
  • Morocco
  • Mozambique
  • Myanmar
  • Namibia
  • Nauru
  • Nepal
  • Netherlands
  • New Zealand
  • Nicaragua
  • Niger
  • Nigeria
  • Niue
  • North Macedonia
  • Norway
  • Oman
  • Pakistan
  • Palau
  • Panama
  • Papua New Guinea
  • Paraguay
  • Peru
  • Philippines
  • Poland
  • Portugal
  • Qatar
  • Republic of Korea
  • Republic of Moldova
  • Romania
  • Russian Federation
  • Rwanda
  • Saint Kitts and Nevis
  • Saint Lucia
  • Saint Vincent and the Grenadines
  • Samoa
  • San Marino
  • Sao Tome and Principe
  • Saudi Arabia
  • Senegal
  • Serbia
  • Seychelles
  • Sierra Leone
  • Singapore
  • Slovakia
  • Slovenia
  • Solomon Islands
  • Somalia
  • South Africa
  • South Sudan
  • Spain
  • Sri Lanka
  • Sudan
  • Suriname
  • Sweden
  • Switzerland
  • Syrian Arab Republic
  • Tajikistan
  • Thailand
  • Timor-Leste
  • Togo
  • Tokelau
  • Tonga
  • Trinidad and Tobago
  • Tunisia
  • Turkey
  • Turkmenistan
  • Tuvalu
  • Uganda
  • Ukraine
  • United Arab Emirates
  • United Kingdom of Great Britain and Northern Ireland
  • United Republic of Tanzania
  • United States of America
  • Uruguay
  • Uzbekistan
  • Vanuatu
  • Venezuela (Bolivarian Republic of)
  • Viet Nam
  • Yemen
  • Zambia
  • Zimbabwe
Country *
Field is required!
Field is required!
Telephone number *
Field is required!
Field is required!
E-mail *
Field is required!
Field is required!
Quantity
Field is required!
Field is required!

Description

PDU-70 POWER DISTRIBUTION UNIT FOR ELECTRIC VEHICLE

EN TECHNICAL DOCUMENT

CAN COMMUNICATIO

PDU-70 uses SAE J-1939 standart CAN protocol in order to communicate with the electrical control unit (ECU). 250kbit/s bit rate is chosen in order to provide reliable operation.

The cyclic status messages are transmitted by the PDU-70 in every 100 ms and the cyclic command message is expected from the ECU in every 100 ms. If the command message is not received by the PDU-70 for 400 ms, the emergency output is asserted (logic high) in order to indicate fault but the operational state of the PDU-70 stays the same in order to give the ECU to control the whole system. For the sake of the operation, the PDU-70 should be taken into low power mode as soon as possible. The details of the CAN messages can be found in log file.

RS422 COMMUNICATION

PDU-70 uses RS422 communication in order to send status messages to the diagnostic/ record device in the system. The PDU-70 does not receive any message through RS422, hence no operational change can be performed. By using RS422 communication, a secondary check to CAN communication can be provided.

TRACTION VOLTAGE POWER DISTRIBUTION UNIT FOR ELECTRIC VEHICLES TRACTION AND AUXLIARY HIGH VOLTAGE SYSTEMS INCLUDING:

– Active unit include traction voltage contactors and contactor controls with Voltage and current measurement units.
– Pre-charging circuit to balance voltage levels before and after contactors
– Service charging circuit with contactor switching
– High voltage circuit insulation resistance measurement & monitoring
– Fuse protection for high and low current component output
– Hazardous voltage interlock loop (HVIL)

Additional information

Operating Voltage Range

10 – 800 VDC

Power Input

Battery Input 1 / 300 A
Battery Input 2 / 300 A
Battery Input 3 / 300 A
Battery Input 4 / 300 A
DC Charge Input / 400 A

Power Output

Traction Inverter / 600 A
PTO Inverter / 125 A
On Board Changer / 50 A
Air Compressor / 30 A
Heater / 25 A
DC-DC Converter / 25 A
A/C Compressor / 30 A

Current Peak

600 A

Interlock Line (“HVIL”) Current

Adjustable (Default: 35 mA)

Interlock Line (“HVIL”) Voltage

36 VDC

Max Voltage Drop over HVIL Loop

Adjustable (Default: 12 VDC)

Interfaces

CAN Bus SAE J-1939 RS422/485

Sign Up For Newsletters

Don’t miss AFSS latest news and events.
Invalid or empty email
You have successfully subscribed to the newsletter.
Something went wrong. Your subscription failed.
ausa_logo
chillpak-hubzone-certification
iso-9001-son-revizyonu
Ares Fire and Safety Systems LLC

AFSS designates as prior aim to transfer quick solutions, impartial, reliable and exact information in accordance with system requirements to costumers.

Need Help?
Our sales consultant will get back to you immediately.
Contact Us
Contact
1675 S. Orange Blossom Trail Apopka, FL 32703
(407) 614-7209

 Copyright © AFSS

WeCreativez WhatsApp Support
Our customer support team is here to answer your questions. Ask us anything!
👋 Hi, how can I help?